Charge Controller
Manufacturer & Exporter of Charge Controller. Our product range also comprises of Permanent Magnet Generator, Emergency Overspeed Governor and Permanent Magnet Motor.
With the goal of delivering qualitative products, we are engaged in providing our clients with an excellent quality Charge Controller. These products are used to rectify frequency-variable output voltage of the wind turbine generator to DC voltage prior to feeding into the grid tie inverter. Offered array is not only protecting against overvoltage for the wind turbine system but also providing the replaced load when the grid is down.
Features:
Product Descriptions:
The PM Charge Controller with dump load is used to rectify frequency-variable output voltage of the wind turbine generator to DC voltage before feeding into the grid tie inverter. It is not only protecting against overvoltage for the wind turbine system, but providing the replaced load when the grid is down. There are three different voltage protecting points you can set in the controller.
Features of 20kW Charge Controller:
Specifications:
Features:
- Application specific design
- Low maintenance
- Easy installation
Product Descriptions:
The PM Charge Controller with dump load is used to rectify frequency-variable output voltage of the wind turbine generator to DC voltage before feeding into the grid tie inverter. It is not only protecting against overvoltage for the wind turbine system, but providing the replaced load when the grid is down. There are three different voltage protecting points you can set in the controller.
Features of 20kW Charge Controller:
- Wide input voltage range of 30 Vac-500Vac
- Flexible dump load point control and action point can be controlled by a toggle switch
- IP65 ingress protection ensures the controller working in outdoor and indoor conditions
- High efficiency ensures efficient power transmission
Specifications:
Controllers Specification | |||
Item | Unit | Parameter | Remarks |
Rating input power | W | 20k | - |
Max input voltage | Vac | 500AC | Line-line |
Max input current | Aac | 40 | - |
Rating DC output voltage | W | 12k | - |
Max DC output voltage | Vdc | 750 | - |
Max DC out current | Adc | 40A | - |
The range of connect dump load: | - | 1) 300V-400V 2) 400V-500V 3) 500V-600V | Four different ranges ranges are available for choice |
Rating Dump load output power | W | 8k | - |
Max Dump load output voltage | Vdc | 750 | - |
Max Dump load output current | Adc | 30 | - |
Efficiency | % | >99.3 | Rating power |
Operation environment temperature | 25-60 | - | |
Protection degree | - | IP65 | - |
Width/ height/ depth | mm | 370*275*135 | - |
Weight | kG | 6.4 | - |